{"id":8711,"date":"2026-05-07T13:30:09","date_gmt":"2026-05-07T05:30:09","guid":{"rendered":"https:\/\/www.microcybers.com\/?p=8711"},"modified":"2026-05-07T15:39:42","modified_gmt":"2026-05-07T07:39:42","slug":"guia-de-selecao-transmissor-de-temperatura-ncs-tt105","status":"publish","type":"post","link":"https:\/\/www.microcybers.com\/pt\/guia-de-selecao-transmissor-de-temperatura-ncs-tt105\/","title":{"rendered":"Guia de Sele\u00e7\u00e3o | Transmissor de Temperatura NCS-TT105 HART, FF H1, PROFIBUS PA"},"content":{"rendered":"<p>O <a href=\"https:\/\/www.microcybers.com\/pt\/produtos\/transmissores-de-temperatura-inteligentes\/montado-em-campo\/\"><strong>Transmissor de temperatura NCS-TT105<\/strong><\/a> \u00e9 um dispositivo inteligente de alto desempenho projetado para automa\u00e7\u00e3o industrial, suportando <strong>HART 7<\/strong>, <strong>FOUNDATION Fieldbus H1<\/strong>, e <strong>PROFIBUS PA<\/strong> protocolos. Este transmissor de canal duplo \u00e9 projetado para medi\u00e7\u00f5es precisas de RTD e termopar em ambientes exigentes, como as ind\u00fastrias de petr\u00f3leo e qu\u00edmica.<\/p>\n<p><a href=\"https:\/\/www.microcybers.com\/pt\/produtos\/transmissores-de-temperatura-inteligentes\/montado-em-campo\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-8717 size-large\" src=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-1024x585.png\" alt=\"Transmissores de Temperatura Montados em Campo\" width=\"800\" height=\"457\" srcset=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-1024x585.png 1024w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-300x171.png 300w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-768x439.png 768w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-18x10.png 18w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638.png 1162w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas Principais<\/h2>\n<ul>\n<li><strong>Protocolos:<\/strong> HART 7, FOUNDATION Fieldbus H1 (certificado ITK 6), PROFIBUS PA.<\/li>\n<li><strong>Tipos de Entrada:<\/strong> Suporta diversos RTDs (ex: Pt100) e Termopares (Tipos E, K, B, etc.).<\/li>\n<li><strong>Canais:<\/strong> Capacidade de canal duplo para medi\u00e7\u00e3o de temperatura diferencial ou m\u00e9dia.<\/li>\n<li><strong>Classifica\u00e7\u00f5es de Seguran\u00e7a:<\/strong> Dispon\u00edvel em <strong>Ex d (\u00e0 prova de explos\u00e3o)<\/strong> e <strong>Ex ia (\u00e0 Prova de Explos\u00e3o intrinsecamente segura)<\/strong> vers\u00f5es.<\/li>\n<\/ul>\n<h2>Recursos Avan\u00e7ados de Medi\u00e7\u00e3o<\/h2>\n<p>O NCS-TT105 oferece modos de medi\u00e7\u00e3o especializados para aprimorar a precis\u00e3o do processo:<\/p>\n<ul>\n<li><strong>Temperatura Diferencial:<\/strong> Defina SENSOR_MEAS_TYPE para \u2018Diferencial\u2019 para exibir a diferen\u00e7a entre dois sensores (PV = SV1 \u2013 SV2), ideal para monitoramento de trocadores de calor.<\/li>\n<li><strong>Compensa\u00e7\u00e3o de Jun\u00e7\u00e3o Fria de Precis\u00e3o:<\/strong> Para aplica\u00e7\u00f5es de termopar de alta precis\u00e3o, um RTD Pt100 no Canal 2 pode servir como refer\u00eancia de jun\u00e7\u00e3o fria para o Canal 1.<\/li>\n<li><strong>Precis\u00e3o Otimizada<\/strong> Termopares do tipo E fornecem a maior precis\u00e3o (\u00b10,20\u00b0C a 25\u00b0C) para necessidades criog\u00eanicas ou aplica\u00e7\u00f5es especializadas de alta sa\u00edda.<\/li>\n<\/ul>\n<h2>Prote\u00e7\u00e3o \u00e0 Prova de Explos\u00e3o: Ex d vs. Ex ia<\/h2>\n<p>Dependendo da sua zona de instala\u00e7\u00e3o, o NCS-TT105 oferece dois m\u00e9todos de prote\u00e7\u00e3o prim\u00e1rios:<\/p>\n<ul>\n<li><strong>Ex d (\u00c0 prova de explos\u00e3o):<\/strong> Utiliza um inv\u00f3lucro refor\u00e7ado (Ex db IIC T5\/T6 Gb) para conter igni\u00e7\u00f5es internas. Ideal para \u00e1reas da Zona 1 que exigem prensa-cabos certificados.<\/li>\n<li><strong>Ex ia (Seguro Intr\u00ednseco):<\/strong> Limita a energia do circuito (Ex ia [ia Ga] IIC T4\/T6 Ga) para prevenir igni\u00e7\u00e3o totalmente. Adequado para Zona 0\/1 e permite manuten\u00e7\u00e3o com o equipamento energizado com uma barreira de seguran\u00e7a certificada.<\/li>\n<\/ul>\n<hr \/>\n<h2>Perguntas Frequentes (FAQ)<\/h2>\n<section>\n<h3>Qual \u00e9 a diferen\u00e7a entre as prote\u00e7\u00f5es Ex d e Ex ia no NCS-TT105?<\/h3>\n<p>Ex d utiliza um inv\u00f3lucro refor\u00e7ado para conter igni\u00e7\u00f5es internas, adequado para a Zona 1. Ex ia limita a energia do circuito para evitar igni\u00e7\u00f5es, tornando-o adequado para a Zona 0\/1 e permitindo manuten\u00e7\u00e3o com o equipamento energizado com uma barreira de seguran\u00e7a.<\/p>\n<\/section>\n<section>\n<h3>O NCS-TT105 pode medir temperatura diferencial?<\/h3>\n<p>Sim. No modo dual-channel, o dispositivo pode emitir a diferen\u00e7a entre dois sensores (PV = SV1 \u2013 SV2), que \u00e9 comumente usada para medi\u00e7\u00e3o de delta-T em trocadores de calor.<\/p>\n<\/section>\n<section>\n<h3>O comprimento m\u00e1ximo do cabo para FOUNDATION Fieldbus H1 \u00e9 de 1.200 metros (3.937 p\u00e9s) em um \u00fanico segmento, com redu\u00e7\u00e3o da dist\u00e2ncia com mais dispositivos no segmento.<\/h3>\n<p>O comprimento m\u00e1ximo do segmento \u00e9 de 1.900 metros. Isso pode ser estendido at\u00e9 10 km usando repetidores.<\/p>\n<\/section>\n<section>\n<h3>Qual tipo de termopar oferece a melhor precis\u00e3o?<\/h3>\n<p>O termopar Tipo E oferece a melhor precis\u00e3o com \u00b10,20\u00b0C (a 25\u00b0C), seguido pelo Tipo K para uso geral em altas temperaturas.<\/p>\n<\/section>\n<section>\n<h3>Qual \u00e9 a tens\u00e3o de alimenta\u00e7\u00e3o necess\u00e1ria para o HART 7?<\/h3>\n<p>A variante HART exige uma tens\u00e3o de alimenta\u00e7\u00e3o de 11,5 a 45 VCC e uma resist\u00eancia de malha de 230-550 \u03a9 para comunica\u00e7\u00e3o.<\/p>\n<\/section>\n<section>\n<h3>Posso usar um RTD como refer\u00eancia de jun\u00e7\u00e3o fria?<\/h3>\n<p>Sim. Um Pt100 conectado ao Canal 2 pode ser configurado como a refer\u00eancia de jun\u00e7\u00e3o fria para um termopar no Canal 1 para melhorar a precis\u00e3o al\u00e9m do sensor interno.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>O transmissor de temperatura NCS-TT105 \u00e9 um dispositivo inteligente de alto desempenho projetado para automa\u00e7\u00e3o industrial, compat\u00edvel com os protocolos HART 7, FOUNDATION Fieldbus H1 e PROFIBUS PA. Este transmissor de canal duplo foi projetado para medi\u00e7\u00f5es precisas de RTD e termopar em ambientes exigentes, como as ind\u00fastrias de petr\u00f3leo e qu\u00edmica. Especifica\u00e7\u00f5es T\u00e9cnicas Principais Protocolos: HART 7, FOUNDATION Fieldbus H1 (certificado ITK 6), [\u2026]<\/p>","protected":false},"author":30,"featured_media":8714,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"page_builder":"","footnotes":""},"categories":[37,38],"tags":[],"class_list":["post-8711","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-and-events","category-products-and-services"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide<\/title>\n<meta name=\"description\" content=\"Smart temperature transmitter for RTD &amp; thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide &amp; datasheet.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.microcybers.com\/pt\/guia-de-selecao-transmissor-de-temperatura-ncs-tt105\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide\" \/>\n<meta property=\"og:description\" content=\"Smart temperature transmitter for RTD &amp; thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide &amp; datasheet.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.microcybers.com\/pt\/guia-de-selecao-transmissor-de-temperatura-ncs-tt105\/\" \/>\n<meta property=\"og:site_name\" content=\"Microcyber\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-07T05:30:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-07T07:39:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"author\" content=\"Dengdeng Yu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Fiv4934Five\" \/>\n<meta name=\"twitter:site\" content=\"@Fiv4934Five\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dengdeng Yu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Guia de Sele\u00e7\u00e3o | Transmissor de Temperatura NCS-TT105 HART, FF H1, PROFIBUS PA","description":"Transmissor de temperatura inteligente para entradas RTD e termopar. Suporta HART 7, FF H1, PROFIBUS PA. Canal duplo, classifica\u00e7\u00e3o Ex d\/Ex ia. Guia de sele\u00e7\u00e3o completo e folha de dados.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.microcybers.com\/pt\/guia-de-selecao-transmissor-de-temperatura-ncs-tt105\/","og_locale":"pt_BR","og_type":"article","og_title":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide","og_description":"Smart temperature transmitter for RTD & thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide & datasheet.","og_url":"https:\/\/www.microcybers.com\/pt\/guia-de-selecao-transmissor-de-temperatura-ncs-tt105\/","og_site_name":"Microcyber","article_published_time":"2026-05-07T05:30:09+00:00","article_modified_time":"2026-05-07T07:39:42+00:00","og_image":[{"width":700,"height":355,"url":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","type":"image\/gif"}],"author":"Dengdeng Yu","twitter_card":"summary_large_image","twitter_creator":"@Fiv4934Five","twitter_site":"@Fiv4934Five","twitter_misc":{"Escrito por":"Dengdeng Yu","Est. tempo de leitura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/","url":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/","name":"Guia de Sele\u00e7\u00e3o | Transmissor de Temperatura NCS-TT105 HART, FF H1, PROFIBUS PA","isPartOf":{"@id":"https:\/\/www.microcybers.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","datePublished":"2026-05-07T05:30:09+00:00","dateModified":"2026-05-07T07:39:42+00:00","author":{"@id":"https:\/\/www.microcybers.com\/#\/schema\/person\/aab0343fd3a86eb085e46ede0b15cf85"},"description":"Transmissor de temperatura inteligente para entradas RTD e termopar. Suporta HART 7, FF H1, PROFIBUS PA. Canal duplo, classifica\u00e7\u00e3o Ex d\/Ex ia. Guia de sele\u00e7\u00e3o completo e folha de dados.","breadcrumb":{"@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#primaryimage","url":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","contentUrl":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","width":700,"height":355,"caption":"NCS-TT105 Temperature Transmitter"},{"@type":"BreadcrumbList","@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.microcybers.com\/"},{"@type":"ListItem","position":2,"name":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.microcybers.com\/#website","url":"https:\/\/www.microcybers.com\/","name":"Microcyber","description":"HART, FF, PA Fieldbus Solutions &amp; Smart Industrial Instruments","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.microcybers.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Person","@id":"https:\/\/www.microcybers.com\/#\/schema\/person\/aab0343fd3a86eb085e46ede0b15cf85","name":"Dengdeng Yu","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/www.microcybers.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/879c2e4746f3c180a838e72a5aa573e1b4238464e20a7f605e998e8a9dd569d3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/879c2e4746f3c180a838e72a5aa573e1b4238464e20a7f605e998e8a9dd569d3?s=96&d=mm&r=g","caption":"Dengdeng Yu"},"description":"Engenheiro S\u00eanior de Fieldbus na Microcyber com mais de 20 anos de experi\u00eancia em automa\u00e7\u00e3o industrial e protocolos de comunica\u00e7\u00e3o HART\/Fieldbus. Pesquisador anterior no Instituto de Automa\u00e7\u00e3o de Shenyang, Academia Chinesa de Ci\u00eancias. Especializado em design de modem HART, desenvolvimento de interface Foundation Fieldbus e integra\u00e7\u00e3o de redes industriais. Contribuidor t\u00e9cnico para m\u00faltiplos padr\u00f5es IEC de fieldbus.","sameAs":["https:\/\/www.microcybers.com","https:\/\/www.linkedin.com\/in\/dengdeng-yu-6595893b9\/"],"url":"https:\/\/www.microcybers.com\/pt\/author\/microcyber\/"}]}},"_links":{"self":[{"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/posts\/8711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/users\/30"}],"replies":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/comments?post=8711"}],"version-history":[{"count":3,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/posts\/8711\/revisions"}],"predecessor-version":[{"id":8718,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/posts\/8711\/revisions\/8718"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/media\/8714"}],"wp:attachment":[{"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/media?parent=8711"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/categories?post=8711"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.microcybers.com\/pt\/wp-json\/wp\/v2\/tags?post=8711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}