NCS-FI105 Fieldbus to Current Converter – FF/PA to 4-20mA | 4 Channels

Who is this for?

If you are a control system engineer, plant operator, system integrator, or maintenance manager working with FOUNDATION Fieldbus (FF) or PROFIBUS PA networks, and you need to interface fieldbus systems with conventional analog control valves, actuators, or other 4-20mA devices, the NCS-FI105 is built for you.

What problem does it solve?

Modern fieldbus systems (FF and PA) offer powerful digital communication, but many final control elements – such as control valves, positioners, and actuators – still accept only conventional 4-20mA analog signals. This creates a compatibility gap that forces engineers to choose between advanced fieldbus control and legacy analog devices.

The NCS-FI105 eliminates this gap. It is a fieldbus to current converter that receives digital fieldbus signals from FF or PA networks and converts them into 4-channel 4-20mA analog output signals. This allows your fieldbus control system to seamlessly operate analog actuators, control valves, and other current-driven devices without costly replacements or complex interface hardware.

Why Microcyber?

Microcyber Corporation is a national high-tech enterprise founded by the Shenyang Institute of Automation, Chinese Academy of Sciences. We developed China’s first internationally certified fieldbus protocol master stack, the first domestically certified fieldbus instrument, and the first TÜV Germany-certified safety instrument. We co-established the first domestic industrial Ethernet protocol standard EPA and the first industrial wireless communication protocol standard WIA-PA, both recognized as IEC international standards. Our products and technologies have earned two National Science and Technology Progress Awards, one National Science and Technology Invention Award, and we have successfully completed more than 200 large-scale automation projects worldwide. We are ISO 9001:2008 and ISO/TS16949 certified – when you choose NCS-FI105, you are choosing field-proven, mission-critical technology.

Conversor de Saída de Corrente NCS-FI105P

Key Features – What Matters to Engineers and Procurement

Priority How NCS-FI105 Delivers
Suporte a Protocolo Compatível com FOUNDATION Fieldbus (FF) H1 e PROFIBUS PA – one converter for both major fieldbus systems.
Multi-Channel Output Oferece 4 independent 4-20mA analog output channels – control up to four analog devices from a single fieldbus node.
Alta Precisão < 0.05% accuracy – ensures precise analog signal conversion for critical control loops.
Flexible Output Loading Supports load resistance up to 1350Ω – compatible with a wide range of analog actuators and control valves.
Rich Function Blocks FF version includes Resource Block, Transducer Block, Analog Output Block, PID Block, Ratio Block, and Lead Lag Block – enabling advanced control strategies directly in the field.
On-Site Adjustment Magnetic bar operation (Zero/Span holes) and optional LCD display allow full local configuration – channel selection, range setting, bus address, and decimal point adjustment without a communicator.
Fieldbus-Ready Complies with FF Specification and PROFIBUS PA Profile 3.01. Supports both cyclical e non-cyclical data communication.
Rugged Design IP65 protection, wide operating temperature range (-40°C to 85°C), and EMC compliant to IEC 61000 – suitable for harsh industrial environments.

Product Overview – FF and PA Versions

The NCS-FI105 Series is available in two protocol variants:

Modelo Protocolo Target Applications
NCS-FI105F FOUNDATION Fieldbus (FF) H1 FF-based control systems, advanced process control, DeltaV, NI-FBUS
NCS-FI105P PROFIBUS PA PA-based systems, Siemens PDM/Step7, European-origin DCS/PLC

Both versions share the same hardware platform, 4-channel 4-20mA output, and magnetic bar on-site adjustment – only the communication protocol differs.

Function Blocks

NCS-FI105F (FF Version)

Function Block Descrição
Resource Block Contains hardware-associated resource data.
Transducer Block Converts I/O device variables into engineering data.
Display Transducer Block Configures process variables displayed on LCD.
Analog Output Block Transmits output data to transducer block and applies to physical devices.
PID Block Provides setpoint treatment, PV filtering, feed-forward, output tracking, and alarm functions.
Ratio Block Realizes ratio control between two input data.
Lead Lag Block Provides dynamic compensation for feed-forward control.

NCS-FI105P (PA Version)

Function Block Descrição
Physical Block Describes device hardware, identification, and diagnostic information.
Transducer Block Isolates function block from I/O characteristics; handles calibration and linearization.
Analog Output Block Transmits output data to transducer block and applies to physical devices.

Technical Specifications

Basic Parameters

Parâmetro Especificação
Sinal de Entrada Fieldbus (FF H1 / PROFIBUS PA)
Sinal de Saída 4-20mA analog (4 channels)
Output Type NPN collector output
Fonte de Alimentação 9-32 VCC
Current Dissipation (Static) ≤ 14mA
Fieldbus Baud Rate 31.25 kbit/s, current-mode
Insulation Between housing and terminal board: 500 Vrms (707 VDC)
Exibir Optional: 6-digit numeric + 5-character LCD
Temperatura de Operação -40°C to 85°C (no display) / -30°C to 70°C (with display)
Faixa de umidade 0% – 100% RH
Tempo de Inicialização ≤ 5 segundos
Protection Class IP65
EMC Compliance Designed to comply with IEC 61000

Technical Performance

Parâmetro Especificação
Precisão < 0.05%
Maximum Load 1350Ω
Load Power 9-32 VDC (Note: supply voltage ≥ output current × load resistance + 5VDC)
Temperature Effect < ±50 ppm/°C

Physical Properties

Parâmetro Especificação
Conexão Elétrica 1/2-14 NPT
Material of Construction Aluminum
Peso 1.1 kg

Configuration & Software Support

For FF Version (NCS-FI105F):

Ferramenta Descrição
Microcyber Configurator Full configuration and diagnostics
NCS4000 DCS Integrated with Microcyber DCS
NI-FBUS Configurator National Instruments FF configuration
Emerson DeltaV Direct integration with DeltaV system
FF Configurator Standard FF configuration software

Configuration Capabilities:

  • Two-point calibration (CAL_POINT_HI / CAL_POINT_LO)

  • Multi-point calibration (up to 8 points via CAL_CURVE_X / CAL_CURVE_Y)

  • LCD display content configuration (BLOCK_TAG_X, RELATIVE_INDEX_X, SUB_INDEX, MNEMONIC_X, DECI_PNT_NUMB_X, ACTIVE_X)

For PA Version (NCS-FI105P):

Ferramenta Descrição
Siemens Simatic PDM Full device management and configuration
Siemens Step7 Hardware configuration and cyclic data setup

Configuration Capabilities:

  • Two-point linearization calibration (via Calibration menu)

  • Bus address setting (0-126)

  • Measurement value display source selection

  • Decimal point position setting

  • Linearization type selection (factory / user)

Cyclical Data Communication: Supports PROFIBUS DP cyclical data exchange via DP/PA coupler or linker. GSD file provided for easy integration with Siemens Step7.

Non-Cyclical Data Communication: Supports PROFIBUS DP non-cyclical data exchange via Class 2 master (e.g., CP5611) using SIMATIC PDM.

On-Site Adjustment – Magnetic Bar Operation

The NCS-FI105 features magnetic bar operation through two jacks marked “SPAN” and “ZERO” on top of the electronic housing. Four virtual keys are simulated:

  • [M] Mode Key – Switch between operable modes

  • [↑] Input Adjustment Key – Increment values

  • [↓] Input Adjustment Key – Decrement values

  • [Enter] Confirmation Key – Execute confirmation

Supported Adjustment Functions – NCS-FI105F (FF Version):

Mode Função Descrição
02 Channel Selection Set channel number (CH_1 to CH_4)
16 Lower Range Limit Adjust characteristic curve lower limit
17 Upper Range Limit Adjust characteristic curve upper limit

Supported Adjustment Functions – NCS-FI105P (PA Version):

Mode Função Descrição
02 Channel Selection Set display channel (CH_1 to CH_4 or LOOP)
11 Display Source Select FINAL_VALUE, RETURN_VALUE, or AO_SETPOINT
13 Bus Address Set PROFIBUS user address (0-126)
14 Decimal Point Set decimal point position (up to 5 decimals)
22 Linearization Type Select factory calibration or user calibration

General Operation:

  1. In measurement value display mode, press [M] to switch modes.

  2. When desired mode is displayed, remove both magnetic sticks.

  3. Press [↑] or [↓] to adjust value.

  4. Press [Enter] to confirm.

  5. Press [M] to return to measurement display.

Restore Factory Defaults:

  1. Turn off power.

  2. Insert both magnetic bars into Zero and Span holes simultaneously.

  3. Turn on power – LCD displays “RST?”.

  4. Remove both bars, then re-insert both bars until progress bar reaches 100%.

  5. Remove both bars – LCD displays “R_OK” when successful.

Nota: If no key operation occurs within 1 minute (no magnetic sticks inserted), the device automatically returns to normal display mode.

Jumper Configuration

NCS-FI105F (FF Version) and NCS-FI105P (PA Version)

Jumper Função Descrição
SIM Simulation Jumper Enables simulation mode for testing
WP Write Protection Jumper Prevents configuration changes when enabled
RST Factory Reset Jumper Restores all configuration to factory defaults

Important Notes:

  • When using RST jumper to restore factory defaults, power off the transmitter, remove the RST jumper, then power on again. If the RST jumper remains in place, configuration data will revert to factory defaults every time the device restarts.

  • WP jumper (write protection) prevents any accidental or unauthorized changes to device configuration – ideal for critical installations.

Typical Applications

  • Control Valve Interface – Convert fieldbus signals to 4-20mA for controlling pneumatic or electric control valves

  • Actuator Control – Interface fieldbus DCS/PLC with analog actuators in process plants

  • Legacy Analog Device Integration – Connect modern fieldbus systems to existing analog instruments without replacing hardware

  • Multi-Device Control – One fieldbus node controls up to four analog devices simultaneously

  • Retrofit Projects – Upgrade plant control systems to fieldbus while preserving existing analog final control elements

Installation & Wiring

Mounting Options:

  • Pipe mounting flat bracket (vertical pipe, Φ50mm)

  • Plate mounting angle bracket (panel/dashboard)

  • Pipe mounting angle bracket (horizontal pipe, Φ50mm)

Fiação:

  • Power and signal share a single pair of cables (bus cable).

  • Use IEC 61158-2 recommended fieldbus cables for FF/PA.

  • Terminal board located on rear cover side.

  • Signal wires should be single-point grounded.

  • Bus cable shield should be floating on converter side, grounded on bus power side.

  • Bus cable should not share conduits or trunks with other equipment power lines.

Terminal Board Pinout:

  • Terminal board connects fieldbus, current output signal, D/A board, and communication board.

Ordering Information

Modelo Protocolo Canais Saída Power
NCS-FI105F FOUNDATION Fieldbus H1 4 4-20mA 9-32 VCC
NCS-FI105P PROFIBUS PA 4 4-20mA 9-32 VCC

Options:

  • LCD Display – Optional 6-digit numeric + 5-character LCD with backlight

  • Display Configuration – Customizable via function block parameters

Accessories:

  • Mounting brackets (pipe flat / plate angle / pipe angle)

  • U-bolts for pipe mounting

Download & Resources

Download Full User Manual (V2.3) 