M0313 Modbus to FOUNDATION Fieldbus Built-in Module – Convert Modbus RTU to FF H1

Visão Geral do Produto

M0313 is a compact Modbus-to-FOUNDATION Fieldbus conversion module designed for integrating Modbus RTU devices into FOUNDATION Fieldbus systems. Operating as a Modbus master, the module communicates with Modbus RTU slave devices through its serial interface and maps Modbus data to FOUNDATION Fieldbus device variables and function blocks.

The M0313 is one of the Microcyber M-series built-in modules, featuring a unified 65 × 42 mm form factor and a 16-pin 2.54 mm pitch connector. By embedding the M0313 into equipment with Modbus RTU communication capabilities, the user equipment can be converted into a FOUNDATION Fieldbus H1 device.

This means you can take an existing Modbus instrument and turn it into a FOUNDATION Fieldbus-compliant field device with minimal hardware changes, without developing a FOUNDATION Fieldbus protocol stack from scratch.

Key Features

  • Modbus RTU to FOUNDATION Fieldbus conversion – Enables Modbus RTU devices to communicate with FF H1 networks
  • Modbus master operation – The module actively polls the connected Modbus slave device
  • Compact 65 × 42 mm module design – Standard M-series form factor for easy integration
  • 16-pin, 2.54 mm pitch interface – Compatible with all Microcyber M-series modules
  • Supports 1 Modbus slave device – Dedicated connection for single-device integration
  • Up to 32 I/O channels – 8 AI, 8 AO, 8 DI, and 8 DO channels
  • FF function blocks – Supports Resource Block, Modbus Transducer Block, AI, AO, DI, DO, and PID
  • Flexible Modbus configuration – Configurable register address, data format, and function code
  • Easy module replacement and protocol upgrading – Swap M-series modules to change protocols

Modbus RTU to FOUNDATION Fieldbus Integration

The M0313 enables Modbus RTU slave devices to be integrated into FOUNDATION Fieldbus systems without redesigning the complete field device communication architecture.

The module operates as a Modbus master and retrieves data from a Modbus RTU slave device. The acquired data is mapped into the module’s Modbus Transducer Block and transferred through FOUNDATION Fieldbus function blocks such as AI, AO, DI, and DO.

As a FOUNDATION Fieldbus device, the module communicates with Modbus devices through simple configuration and transfers data to the control system via the FF bus.

M0313 Modbus to FOUNDATION Fieldbus Built-in Module – Convert Modbus RTU to FF H1

How the M0313 Works

The M0313 works as a communication bridge between a Modbus RTU slave device and a FOUNDATION Fieldbus network.

Modbus RTU Device → M0313 Modbus Interface → Modbus Transducer Block → FF Function Blocks → FOUNDATION Fieldbus Control System

The module reads Modbus register data and maps the data into transducer block parameters. The mapped process data can then be transferred to AI, AO, DI, and DO function blocks for communication with the FOUNDATION Fieldbus control system.

The module supports 1 Modbus slave device and provides 8 groups of analog input/output and discrete input/output parameters, totaling 32 channels. It configures Modbus device data into transducer block parameters via Modbus registers and provides data support for the FF system via channels between variables and AI, AO, DI, and DO function blocks.

Aplicativos

  • Integrating Modbus RTU transmitters into FOUNDATION Fieldbus networks
  • Upgrading existing Modbus instruments to FF H1 communication
  • OEM field device development with FOUNDATION Fieldbus support
  • Process automation systems requiring Modbus-to-FF protocol conversion
  • Retrofit projects where instruments need FF communication without full redesign

Technical Specifications

Parâmetro Especificação
Supported Modbus Device Modbus RTU slave device
FF Bus Power 9–32 VDC
Corrente de Quiescência ≤14 mA
Bus Protocol Two-wire FOUNDATION Fieldbus H1
Tensão de Isolamento 1000 V AC between Modbus and FF interface
Temperatura de Operação -40°C a +85°C
Operating Humidity 5–95% RH
Start-up Time ≤5 s
Tempo de Atualização 0,2 s
Peso 16 g
Module Size 65 × 42 mm
Interface TTL level

Supported Modbus Function Codes

The M0313 supports the following Modbus function codes:

Código da Função Descrição
01 Read Coil Status
02 Read Discrete Input Status
03 Read Holding Registers
04 Read Input Registers
05 Write Single Coil
06 Write Single Register
15 Write Multiple Coils
16 Write Multiple Registers

FOUNDATION Fieldbus Function Blocks

The default configuration includes the following function blocks:

Function Block Descrição
Resource Block (RES) Device identification in the field
Modbus Transducer Block (MTB) Configures Modbus communication parameters
Analog Input (AI) × 8 Transducer block input data with range conversion and square root
Analog Output (AO) × 8 Transfers output data to transducer block
Discrete Input (DI) × 8 Achieves transducer block input data
Discrete Output (DO) × 8 Transfers discrete output data to transducer block
PID Block PID control with setpoint adjustment and PV filtering

AI, AO, DI, and DO support up to 8 channels each, corresponding to analog/discrete input and output parameters of the Modbus Transducer Block.

Hardware Interface

The M0313 uses a 2.54 mm pitch 16-pin connector (JP1) to connect to the user board.

Pin definition (JP1):

Fixar I/O Nome Descrição
1 I IVCC_IS Signal isolated power supply (provided by baseboard)
2 I IGND_IS Signal isolated power ground (provided by baseboard)
3 I /RES CPU reset, low active
5 O TXD CPU serial data transmission
6 O RTS RS-485 control port
8 I RXD CPU serial data receiving
10 I/O Status Communication status indicator
11 I/O BUS+ Bus power supply positive
12 I/O BUS- Bus power supply negative

DIP Switch Configuration

The M0313 has two DIP switches: a 3-position switch S1 and an 8-position switch S2.

S1 (3-position DIP switch):

No. Nome Descrição
1 RST Reset — restores device data to factory defaults
2 WP Write protection — prevents configuration changes
3 S/E Simulation switch — used for simulation function

S2 (8-position DIP switch):

No. Descrição
1–7 Reserved (do not modify)
8 (M) Working mode: ON = Configuration mode, OFF = Normal working mode

Modbus Configuration

The M0313 can be configured through the Modbus General Configuration Tool provided by Microcyber. Users can define the communication parameters of the Modbus slave device and configure register addresses, data formats, read/write modes, and Modbus function codes.

Configuration process:

  1. Enter Configuration Mode — Set position M of DIP switch S2 to ON
  2. Connect to the Modbus Device — Open the Modbus configuration tool, configure the serial port, and scan the connected slave device
  3. Configure Communication Parameters — Configure baud rate, data bits, parity, stop bits, physical interface, slave address, and timeout according to the Modbus slave device
  4. Configure Data Parameters — Select the required function code, data type, and register address for each parameter
  5. Validate and Download — Set the data configuration status to “Data Valid” and download the configuration to the device
  6. Return to Normal Operation — Set position M of DIP switch S2 to OFF and connect the device to the FOUNDATION Fieldbus network

Default communication parameters:

Parâmetro Default Value
Slave Address 1
Baud Rate 9600
Data Bits 8
Stop Bits 1
Parity Even
CRC Byte Order Low byte first
Timeout 300 ms
Retry Times 3

Configuration Example

The following example shows how to configure the M0313 for a typical Modbus slave device.

Modbus slave device parameters:

Parâmetro Valor
Baud Rate 9600 bps
Data Bits 8
Parity Even
Physical Standard TTL
Stop Bits 1
Slave Address 1
CRC Order Normal
Timeout 300 ms
Retry Times 3

Register mapping example:

Register Address Data Format Definition
4112 Float Instantaneous flow
4114 Float Instantaneous velocity
4116 Float Flow percentage
4118 Float Fluid conductance ratio
4120 Long Integer part of positive accumulation
4122 Float Decimal part of positive accumulation
4128 Unsigned short Unit of instantaneous flow
4129 Unsigned short Unit of accumulation total

M0313 Troubleshooting Guide

Sintoma Causa Possível Ação Recomendada
FF communication LED off No FF communication / power fault Check FF master, interface, power supply, and wiring
Modbus LED off Slave device not connected Check slave device and connection
Transducer Block cannot enter Auto S2 position M incorrect Set S2-M to OFF in normal operating mode
Communication Failure Incorrect communication parameters Check baud rate, parity, address, timeout, and related settings
Illegal Data Address Incorrect register configuration Check the configured Modbus register address
Illegal Function Incorrect function code Check the configured Modbus function code
Data Type Mismatch Incorrect data type configuration Check the configured parameter data type
Data Integrity Error Communication interruption Check device connections and wiring
Slave Device Failure Modbus slave device error Check the status of the Modbus slave device

Model Selection

M0313 selection code: MOD-FFH1-MNTMN

Código Descrição Option
Master/Slave M Master Station
Module Form N General
Hardware Interface T TTL Level
Software Interface M Modbus RTU
Bus Interface on Module N No Bus Interface

Perguntas Frequentes

What is the M0313 Modbus to FOUNDATION Fieldbus module?

The M0313 is an embedded communication module that allows Modbus RTU slave devices to communicate with FOUNDATION Fieldbus systems. It operates as a Modbus master and maps Modbus data into FOUNDATION Fieldbus device variables.

How many Modbus slave devices does the M0313 support?

The M0313 supports one Modbus slave device. The module provides up to 32 channels through analog and discrete input/output parameters.

What Modbus interface does the M0313 use?

The M0313 communicates with the Modbus RTU device through a TTL-level serial interface.

What FOUNDATION Fieldbus function blocks are supported?

The default configuration includes Resource Block, Modbus Transducer Block, AI (8 channels), AO (8 channels), DI (8 channels), DO (8 channels), and PID function blocks.

What is the operating temperature range?

The specified temperature range is -40°C to +85°C.

What is the FF bus voltage?

The specified FF bus power range is 9–32 VDC.

Is this module suitable for OEM applications?

Yes, the M0313 is designed as a built-in module for OEM and embedded fieldbus device development. The Microcyber M-series uses a unified 65 × 42 mm form factor and a 16-pin 2.54 mm pitch connector, supporting easier hardware integration and module replacement.

Can I create my own GSD file for the M0313?

Yes, the module is sold in OEM mode, and users have independent intellectual property rights for the FOUNDATION Fieldbus devices developed with this module. The Modbus General Configuration Tool can generate a user-specific EDD file based on the provided template.

Downloads

 

Need to integrate a Modbus device into FOUNDATION Fieldbus? Contact our support team for technical assistance and integration support.