MS0210 / MS0213 / MS0207 Temperature Electronic Boards

Product Overview – Built for OEMs Who Want to Launch Faster

Who is this for?
If you are an OEM manufacturer of temperature transmitters, a system integrator, or an automation brand looking to expand your product line, these electronic boards are your shortcut to market.

What problem does it solve?
Developing a multi-protocol, high-accuracy temperature transmitter from scratch takes 18–24 months of R&D, extensive certification testing, and ongoing firmware maintenance. The MS0210/MS0213/MS0207 eliminates that burden. It is a field-proven, off-the-shelf temperature transmitter electronics platform that you can simply integrate into your own housing, configure, and start shipping.

Why Microcyber?
Backed by the Chinese Academy of Sciences (Shenyang Institute of Automation) and a key contributor to IEC international fieldbus standards (EPA, WIA-PA), Microcyber brings over 15 years of industrial communication expertise. We are ISO 9001 certified, have delivered 200+ large-scale automation projects worldwide, and our boards are already deployed in thousands of transmitters across oil & gas, chemical, and power plants. When you choose our module, you are leveraging proven technology – not building it from zero.


FF Network Topology

Why This Board for Your OEM Project?

OEM Priority How MS0210/MS0213/MS0207 Delivers
✅ Protocol Coverage One hardware platform supports HART (4‑20mA + digital), FOUNDATION Fieldbus (FF), y PROFIBUS PA. Stock one board, serve multiple market segments.
✅ Customization Flexibility We support custom sensor polynomials (TC/RTD) , custom calibration curves, y OEM branding (firmware tag, default settings). You retain your unique selling points.
✅ Proven & Mass-Production Ready Factory-calibrated for all common sensors (Pt100, Cu50, T/C B/E/J/K/N/R/S/T). No tweaking required. Just connect your sensor, configure, and go. Over 10,000+ units in field operation.
✅ Replace In-House R&D Avoid the high cost of hiring embedded engineers, writing HART/FF/PA stacks from scratch, and obtaining protocol certifications. This board gives you instant time-to-market at a fraction of the cost.

Technical Highlights – What’s Inside the Board

  • Universal Sensor Inputs – Works as both an RTD temperature transmitter board (Pt100, Cu50, Pt1000, Ni, 2/3/4‑wire) and a thermocouple transmitter board (B, E, J, K, N, R, S, T, plus mV and resistance).

  • Dual‑Channel Design – Measure two sensors simultaneously. Compute average, difference, or redundant (hot backup) values inside the board – perfect for differential temperature or safety-critical redundancy.

  • Alta precisión – ±0.1°C for Pt100, ±0.4°C for K‑type TC, with current output accuracy of 0.03% (HART). Low temperature drift ensures stable performance in harsh environments.

  • Local Configuration – Built‑in support for optional dot‑matrix LCD (90°/180°/360° rotatable) and three push‑buttons ([M], [S], [Z]) for on‑site range, unit, and damping adjustments.

  • Comprehensive Diagnostics – Open/short circuit detection, hardware fault monitoring, and communication error alarms. HART versions support NAMUR NE43 saturation/alarm currents (3.8mA / 20.5mA).


FF bus connection

Supported Protocols – One Board, Three Options

Protocolo Key Features Target Markets
HART 7 4‑20mA loop‑powered, Burst mode, multidrop (up to 64 devices), configurable alarm/saturation currents Retrofit, analog‑to‑digital upgrades, legacy plant integration
FOUNDATION Fieldbus (FF) Standard function blocks (RES, AI, PID, DSP, etc.), peer‑to‑peer communication, DD files provided Greenfield projects, advanced process control, chemical/pharma
PROFIBUS PA Profile 3.02 compliant, 4 AI blocks, cyclic/non‑cyclic data exchange, GSD files for Siemens PDM/Step7 European‑origin systems, power generation, water/wastewater

Configuration & Integration Tools

  • HART: Microcyber HartMPT / Emerson 475 handheld / AMS

  • FF: NI‑FBUS Configurator / Emerson DeltaV / NCS4000

  • PA: Siemens Simatic PDM / Step7 (GSD provided)

All tools allow full parameter read/write, diagnostic access, and calibration routines.


OEM Customization Options (What We Can Tailor)

  • Default sensor type and engineering units

  • Custom TC or RTD polynomial coefficients (up to 5 segments)

  • Pre‑loaded user defaults (saves your factory settings as default)

  • LCD display content and rotation preferences

  • OEM label/descriptor in firmware


Especificaciones técnicas

Parámetro Valor
Input Types RTD (Pt100/Cu50/Pt1000), TC (B/E/J/K/N/R/S/T), Resistance (0‑4000Ω), mV (±100mV)
Canales 2 (independent)
Accuracy (RTD Pt100) ±0.1°C at 25°C
Accuracy (TC K‑type) ±0.4°C at 25°C
Current Accuracy (HART) ±0.03%
Compensación de Unión Fría Internal / External / Sensor2 (±0.5°C)
Amortiguación 0 ~ 32 s (adjustable)
Aislamiento 1000V AC
Potencia HART: 11.5~45V DC / FF/PA: 9~32V DC
Operating Temp -40°C ~ 85°C (no display) / -20°C ~ 70°C (with display)
Dimensiones Ø45 mm (head‑mount) – fits standard thermometer housings

Typical OEM Use Cases

  • Launch your own branded smart temperature transmitter without investing in protocol stack development.

  • Upgrade your existing analog transmitter lineup to digital HART or fieldbus capability with minimal redesign.

  • Build dual‑sensor average/differential transmitters for reactor temperature control or furnace profiling.

  • Replace unreliable third‑party modules with a more stable, better‑supported alternative.


Ordering Information

Option Choices
Protocolo HART / FOUNDATION Fieldbus / PROFIBUS PA
Pantalla With LCD + buttons / Without display
Custom Calibration Standard / Custom polynomial (please specify)

Ready to accelerate your product development?
Contact our OEM support team for samples, technical datasheets, and integration guidance.

[Download Full User Manual V1.4]