{"id":8711,"date":"2026-05-07T13:30:09","date_gmt":"2026-05-07T05:30:09","guid":{"rendered":"https:\/\/www.microcybers.com\/?p=8711"},"modified":"2026-05-07T15:39:42","modified_gmt":"2026-05-07T07:39:42","slug":"temperature-transmitter-ncs-tt105-selection-guide","status":"publish","type":"post","link":"https:\/\/www.microcybers.com\/en\/temperature-transmitter-ncs-tt105-selection-guide\/","title":{"rendered":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide"},"content":{"rendered":"<p>The <a href=\"https:\/\/www.microcybers.com\/en\/products\/smart-temperature-transmitters\/field-mounted\/\"><strong>NCS-TT105 temperature transmitter<\/strong><\/a> is a high-performance smart device designed for industrial automation, supporting <strong>HART 7<\/strong>, <strong>FOUNDATION Fieldbus H1<\/strong>, and <strong>PROFIBUS PA<\/strong> protocols. This dual-channel transmitter is engineered for precise RTD and thermocouple measurements in demanding environments, such as petroleum and chemical industries.<\/p>\n<p><a href=\"https:\/\/www.microcybers.com\/en\/products\/smart-temperature-transmitters\/field-mounted\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-8717 size-large\" src=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-1024x585.png\" alt=\"Field Mounted Temperature Transmitters\" width=\"800\" height=\"457\" srcset=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-1024x585.png 1024w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-300x171.png 300w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-768x439.png 768w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638-18x10.png 18w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/29a0556a-b5dc-4fb4-8cd2-c6bdcfe18638.png 1162w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n<h2>Key Technical Specifications<\/h2>\n<ul>\n<li><strong>Protocols:<\/strong> HART 7, FOUNDATION Fieldbus H1 (ITK 6 certified), PROFIBUS PA.<\/li>\n<li><strong>Input Types:<\/strong> Supports various RTD (e.g., Pt100) and Thermocouple (Types E, K, B, etc.).<\/li>\n<li><strong>Channels:<\/strong> Dual-channel capability for differential or average temperature measurement.<\/li>\n<li><strong>Safety Ratings:<\/strong> Available in <strong>Ex d (Flameproof)<\/strong> and <strong>Ex ia (Intrinsically Safe)<\/strong> versions.<\/li>\n<\/ul>\n<h2>Advanced Measurement Features<\/h2>\n<p>The NCS-TT105 offers specialized measurement modes to enhance process accuracy:<\/p>\n<ul>\n<li><strong>Differential Temperature:<\/strong> Set SENSOR_MEAS_TYPE to &#8216;Differential&#8217; to output the difference between two sensors (PV = SV1 &#8211; SV2), ideal for heat exchanger monitoring.<\/li>\n<li><strong>Precision Cold Junction Compensation:<\/strong> For high-accuracy thermocouple applications, a Pt100 RTD on Channel 2 can serve as the cold junction reference for Channel 1.<\/li>\n<li><strong>Optimized Accuracy:<\/strong> Type E thermocouples provide the highest accuracy (\u00b10.20\u00b0C at 25\u00b0C) for cryogenic or specialized high-output needs.<\/li>\n<\/ul>\n<h2>Explosion-Proof Protection: Ex d vs. Ex ia<\/h2>\n<p>Depending on your installation zone, the NCS-TT105 provides two primary protection methods:<\/p>\n<ul>\n<li><strong>Ex d (Flameproof):<\/strong> Uses a reinforced enclosure (Ex db IIC T5\/T6 Gb) to contain internal ignitions. Best for Zone 1 areas requiring certified cable glands.<\/li>\n<li><strong>Ex ia (Intrinsically Safe):<\/strong> Limits circuit energy (Ex ia [ia Ga] IIC T4\/T6 Ga) to prevent ignition entirely. Suitable for Zone 0\/1 and allows for live servicing with a certified safety barrier.<\/li>\n<\/ul>\n<hr \/>\n<h2>Frequently Asked Questions (FAQ)<\/h2>\n<section>\n<h3>What is the difference between Ex d and Ex ia protection in the NCS-TT105?<\/h3>\n<p>Ex d uses a reinforced enclosure to contain internal ignition, suitable for Zone 1. Ex ia limits circuit energy to prevent ignition, making it suitable for Zone 0\/1 and allowing for live servicing with a safety barrier.<\/p>\n<\/section>\n<section>\n<h3>Can the NCS-TT105 measure differential temperature?<\/h3>\n<p>Yes. In dual-channel mode, the device can output the difference between two sensors (PV = SV1 &#8211; SV2), which is commonly used for heat exchanger delta-T measurement.<\/p>\n<\/section>\n<section>\n<h3>What is the maximum cable length for FOUNDATION Fieldbus H1?<\/h3>\n<p>The maximum segment length is 1,900 meters. This can be extended up to 10 km using repeaters.<\/p>\n<\/section>\n<section>\n<h3>Which thermocouple type offers the best accuracy?<\/h3>\n<p>The Type E thermocouple provides the best accuracy at \u00b10.20\u00b0C (at 25\u00b0C), followed by Type K for general high-temperature use.<\/p>\n<\/section>\n<section>\n<h3>What is the supply voltage required for HART 7?<\/h3>\n<p>The HART variant requires a supply voltage of 11.5 to 45 VDC and a loop resistance of 230-550 \u03a9 for communication.<\/p>\n<\/section>\n<section>\n<h3>Can I use an RTD as a cold junction reference?<\/h3>\n<p>Yes. A Pt100 connected to Channel 2 can be configured as the cold junction reference for a thermocouple on Channel 1 to improve accuracy beyond the internal sensor.<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>The NCS-TT105 temperature transmitter is a high-performance smart device designed for industrial automation, supporting HART 7, FOUNDATION Fieldbus H1, and PROFIBUS PA protocols. This dual-channel transmitter is engineered for precise RTD and thermocouple measurements in demanding environments, such as petroleum and chemical industries. Key Technical Specifications Protocols: HART 7, FOUNDATION Fieldbus H1 (ITK 6 certified), [&hellip;]<\/p>\n","protected":false},"author":30,"featured_media":8714,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"page_builder":"","footnotes":""},"categories":[37,38],"tags":[],"class_list":["post-8711","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-and-events","category-products-and-services"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide<\/title>\n<meta name=\"description\" content=\"Smart temperature transmitter for RTD &amp; thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide &amp; datasheet.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.microcybers.com\/en\/temperature-transmitter-ncs-tt105-selection-guide\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide\" \/>\n<meta property=\"og:description\" content=\"Smart temperature transmitter for RTD &amp; thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide &amp; datasheet.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.microcybers.com\/en\/temperature-transmitter-ncs-tt105-selection-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Microcyber\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-07T05:30:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-07T07:39:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"author\" content=\"Dengdeng Yu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Fiv4934Five\" \/>\n<meta name=\"twitter:site\" content=\"@Fiv4934Five\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dengdeng Yu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide","description":"Smart temperature transmitter for RTD & thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide & datasheet.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.microcybers.com\/en\/temperature-transmitter-ncs-tt105-selection-guide\/","og_locale":"en_US","og_type":"article","og_title":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide","og_description":"Smart temperature transmitter for RTD & thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide & datasheet.","og_url":"https:\/\/www.microcybers.com\/en\/temperature-transmitter-ncs-tt105-selection-guide\/","og_site_name":"Microcyber","article_published_time":"2026-05-07T05:30:09+00:00","article_modified_time":"2026-05-07T07:39:42+00:00","og_image":[{"width":700,"height":355,"url":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","type":"image\/gif"}],"author":"Dengdeng Yu","twitter_card":"summary_large_image","twitter_creator":"@Fiv4934Five","twitter_site":"@Fiv4934Five","twitter_misc":{"Written by":"Dengdeng Yu","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/","url":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/","name":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide","isPartOf":{"@id":"https:\/\/www.microcybers.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","datePublished":"2026-05-07T05:30:09+00:00","dateModified":"2026-05-07T07:39:42+00:00","author":{"@id":"https:\/\/www.microcybers.com\/#\/schema\/person\/aab0343fd3a86eb085e46ede0b15cf85"},"description":"Smart temperature transmitter for RTD & thermocouple inputs. Supports HART 7, FF H1, PROFIBUS PA. Dual-channel, Ex d\/Ex ia rated. Full selection guide & datasheet.","breadcrumb":{"@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#primaryimage","url":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","contentUrl":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/05\/NCS-TT105-Temperature-Transmitter.gif","width":700,"height":355,"caption":"NCS-TT105 Temperature Transmitter"},{"@type":"BreadcrumbList","@id":"https:\/\/www.microcybers.com\/temperature-transmitter-ncs-tt105-selection-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.microcybers.com\/"},{"@type":"ListItem","position":2,"name":"NCS-TT105 Temperature Transmitter | HART, FF H1, PROFIBUS PA Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.microcybers.com\/#website","url":"https:\/\/www.microcybers.com\/","name":"Microcyber","description":"HART, FF, PA Fieldbus Solutions &amp; Smart Industrial Instruments","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.microcybers.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.microcybers.com\/#\/schema\/person\/aab0343fd3a86eb085e46ede0b15cf85","name":"Dengdeng Yu","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.microcybers.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/879c2e4746f3c180a838e72a5aa573e1b4238464e20a7f605e998e8a9dd569d3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/879c2e4746f3c180a838e72a5aa573e1b4238464e20a7f605e998e8a9dd569d3?s=96&d=mm&r=g","caption":"Dengdeng Yu"},"description":"Senior Fieldbus Engineer at Microcyber with 20+ years of experience in industrial automation and HART\/Fieldbus communication protocols. Former researcher at Shenyang Institute of Automation, Chinese Academy of Sciences. Specialized in HART modem design, Foundation Fieldbus interface development, and industrial network integration. Technical contributor to multiple IEC fieldbus standards.","sameAs":["https:\/\/www.microcybers.com","https:\/\/www.linkedin.com\/in\/dengdeng-yu-6595893b9\/"],"url":"https:\/\/www.microcybers.com\/en\/author\/microcyber\/"}]}},"_links":{"self":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts\/8711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/users\/30"}],"replies":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/comments?post=8711"}],"version-history":[{"count":3,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts\/8711\/revisions"}],"predecessor-version":[{"id":8718,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts\/8711\/revisions\/8718"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/media\/8714"}],"wp:attachment":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/media?parent=8711"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/categories?post=8711"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/tags?post=8711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}