{"id":7988,"date":"2026-03-25T00:20:57","date_gmt":"2026-03-25T08:20:57","guid":{"rendered":"https:\/\/www.microcybers.com\/?p=7988"},"modified":"2026-03-25T00:53:18","modified_gmt":"2026-03-25T08:53:18","slug":"what-is-a-hart-temperature-transmitter","status":"publish","type":"post","link":"https:\/\/www.microcybers.com\/en\/what-is-a-hart-temperature-transmitter\/","title":{"rendered":"What is a HART Temperature Transmitter?"},"content":{"rendered":"<p>If you\u2019ve searched \u201cWhat is a temperature transmitter with HART?\u201d, \u201cWhat is HART in transmitter?\u201d, \u201cWhat is the difference between 4\/20mA and HART?\u201d, \u201cWhat is the smart HART temperature transmitter?\u201d, or \u201cWhat are the 4 types of temperature sensors?\u201d, you\u2019re not alone. These are some of the most common questions engineers, technicians, and procurement teams ask when evaluating process instrumentation.<\/p>\n<p>In this complete 2026 guide, we answer every question clearly and practically. You\u2019ll learn exactly what HART is, how it works inside a temperature transmitter, why smart HART transmitters are now the industry standard, the real difference between classic 4-20mA and HART, and the four primary types of temperature sensors used today. We\u2019ll also use the Microcyber NCS-TT106H as a real-world example of a modern smart HART temperature transmitter.<\/p>\n<h2>What is a Temperature Transmitter with HART?<\/h2>\n<p>A temperature transmitter with HART is an intelligent field device that converts the raw signal from a temperature sensor (RTD or thermocouple) into a standardized 4-20mA analog signal while simultaneously enabling two-way digital communication using the HART protocol.<\/p>\n<p>Unlike a simple temperature sensor that only outputs a weak mV or resistance signal, a HART temperature transmitter does three things at once:<\/p>\n<ul>\n<li>Measures temperature accurately<\/li>\n<li>Converts the signal to a reliable 4-20mA current loop that DCS\/PLC systems understand<\/li>\n<li>Allows digital communication (configuration, diagnostics, and data) over the same two wires<\/li>\n<\/ul>\n<p>This makes it \u201csmart\u201d \u2014 you can install it in a remote, harsh industrial environment (oil &amp; gas, chemical plants, power stations, metallurgy) and still configure or diagnose it from the control room without running extra cables.<\/p>\n<h2><a href=\"https:\/\/www.microcybers.com\/en\/head-mounted-1-ch-hart-temperature-transmitter\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-7992 size-large\" src=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/75e4c5cf-aaba-4e13-ae29-ff946f71275a-1024x468.png\" alt=\"What is HART in a Transmitter?\" width=\"800\" height=\"366\" srcset=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/75e4c5cf-aaba-4e13-ae29-ff946f71275a-1024x468.png 1024w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/75e4c5cf-aaba-4e13-ae29-ff946f71275a-300x137.png 300w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/75e4c5cf-aaba-4e13-ae29-ff946f71275a-768x351.png 768w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/75e4c5cf-aaba-4e13-ae29-ff946f71275a-18x8.png 18w, https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/75e4c5cf-aaba-4e13-ae29-ff946f71275a.png 1504w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/h2>\n<h2>What is HART in a Transmitter?<\/h2>\n<p>HART stands for <a href=\"https:\/\/www.microcybers.com\/en\/head-mounted-1-ch-hart-temperature-transmitter\/\"><strong>Highway Addressable Remote Transducer<\/strong><\/a>. It is an open communication protocol developed in the 1980s that has become the global standard for smart process instruments.<\/p>\n<p>Think of HART as a \u201cdigital overlay\u201d on top of the traditional 4-20mA analog signal. It works by superimposing low-level digital signals (using Frequency Shift Keying \u2014 FSK) onto the same two wires that carry the 4-20mA analog current. This means:<\/p>\n<ul>\n<li>The analog 4-20mA signal continues to work exactly as before<\/li>\n<li>You can send and receive digital commands (read PV, change range, perform diagnostics) at the same time<\/li>\n<\/ul>\n<p>HART is backward-compatible, vendor-neutral, and supported by virtually every major DCS and PLC system in the world.<\/p>\n<h2>What is the Difference Between 4-20mA and HART?<\/h2>\n<p>This is one of the most frequently asked questions. Here\u2019s the clear breakdown:<\/p>\n<table style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\">\n<tbody>\n<tr style=\"background: #f4f4f4;\">\n<th>Feature<\/th>\n<th>Traditional 4-20mA<\/th>\n<th>HART (on top of 4-20mA)<\/th>\n<\/tr>\n<tr>\n<td>Signal Type<\/td>\n<td>Analog only<\/td>\n<td>Analog + Digital (simultaneous)<\/td>\n<\/tr>\n<tr>\n<td>Information Carried<\/td>\n<td>Only one variable (temperature)<\/td>\n<td>Multiple variables + diagnostics + configuration<\/td>\n<\/tr>\n<tr>\n<td>Communication Direction<\/td>\n<td>One-way (field to control room)<\/td>\n<td>Two-way (read &amp; write)<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Requires loop calibrator or manual adjustment<\/td>\n<td>Remote configuration with handheld or software<\/td>\n<\/tr>\n<tr>\n<td>Diagnostics<\/td>\n<td>None<\/td>\n<td>Full device diagnostics, sensor fault detection<\/td>\n<\/tr>\n<tr>\n<td>Max Devices per Loop<\/td>\n<td>1<\/td>\n<td>Up to 64 in multidrop (digital-only) mode<\/td>\n<\/tr>\n<tr>\n<td>Current in Digital Mode<\/td>\n<td>4-20mA varies<\/td>\n<td>Fixed at 4mA (pure digital)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In short: 4-20mA is the reliable analog \u201chighway\u201d. HART is the digital \u201csmartphone\u201d riding on the same highway. Modern plants use both together \u2014 the analog for fast control, HART for intelligence.<\/p>\n<h2>What is a Smart HART Temperature Transmitter?<\/h2>\n<p>A smart <a href=\"https:\/\/www.microcybers.com\/en\/head-mounted-1-ch-hart-temperature-transmitter\/\">HART temperature transmitter<\/a> is the next-generation version of a classic transmitter. It contains a microprocessor that performs:<\/p>\n<ul>\n<li>Linearization and cold-junction compensation for thermocouples<\/li>\n<li>Lead-wire compensation for RTDs<\/li>\n<li>Digital filtering and damping (0\u201332 seconds adjustable)<\/li>\n<li>Self-diagnostics and alarm functions<\/li>\n<li>Remote configuration via HART commands<\/li>\n<\/ul>\n<p>Real-world example: The Microcyber <a href=\"https:\/\/www.microcybers.com\/en\/head-mounted-1-ch-hart-temperature-transmitter\/\"><strong>NCS-TT106H<\/strong><\/a> is a perfect single-channel smart HART temperature transmitter. It supports 8 thermocouple types (B, E, J, K, N, R, S, T), 4 RTD types (PT100, PT1000, CU50, CU100), resistance, and mV signals \u2014 all on one device. It offers \u00b10.15\u00b0C accuracy for PT100, one-click 2-wire zero calibration, and works in both 4-20mA compatible mode and full HART multidrop networking (up to 64 devices).<\/p>\n<h2><a href=\"https:\/\/www.microcybers.com\/en\/head-mounted-1-ch-hart-temperature-transmitter\/\"><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/02\/3-3.png\" alt=\"What Are the 4 Types of Temperature Sensors Used with HART Transmitters\" width=\"1000\" height=\"1000\" \/><\/a><\/h2>\n<h2>What Are the 4 Types of Temperature Sensors Used with HART Transmitters?<\/h2>\n<p>Although there are dozens of temperature sensing technologies, industrial HART transmitters are most commonly paired with these four main types:<\/p>\n<ol>\n<li><strong>RTD (Resistance Temperature Detector)<\/strong> \u2014 Most accurate and stable<br \/>\nBest choice for precision applications (-200\u00b0C to +850\u00b0C). PT100 and PT1000 are the most popular. The NCS-TT106H supports 2-, 3-, and 4-wire RTDs with automatic lead compensation.<\/li>\n<li><strong>Thermocouple (TC)<\/strong> \u2014 Widest temperature range and fastest response<br \/>\nUses two dissimilar metals to generate a tiny voltage. The NCS-TT106H supports 8 types (B, E, J, K, N, R, S, T) with automatic cold-junction compensation (\u00b10.5\u00b0C accuracy).<\/li>\n<li><strong>Thermistor<\/strong> \u2014 High sensitivity at lower temperatures<br \/>\nNot as common in heavy industry but used in HVAC and laboratory applications. Some HART transmitters can accept thermistor curves via resistance input.<\/li>\n<li><strong>Semiconductor \/ IC Sensor<\/strong> \u2014 Low-cost, linear output<br \/>\nDigital output (I\u00b2C, SPI) or analog voltage. Increasingly used in smart buildings and IIoT, though less common in harsh process environments compared to RTDs and TCs.<\/li>\n<\/ol>\n<p>In practice, 95% of industrial HART temperature transmitters are used with either RTD or Thermocouple sensors.<\/p>\n<h2>How Does a Smart HART Temperature Transmitter Actually Work in the Field?<\/h2>\n<p>Step-by-step real-world operation:<\/p>\n<ol>\n<li>The sensor (RTD or TC) sends a raw signal to the transmitter.<\/li>\n<li>The microprocessor linearizes, compensates, and converts it to a precise temperature value.<\/li>\n<li>The transmitter outputs a 4-20mA signal proportional to the temperature (4mA = lower range, 20mA = upper range).<\/li>\n<li>At the same time, HART digital packets travel over the loop for configuration and diagnostics.<\/li>\n<\/ol>\n<p>You can use a HART communicator, laptop with HartMPT software, or any modern asset management system to:<\/p>\n<ul>\n<li>Change the 4-20mA range without touching wires<\/li>\n<li>Set damping time<\/li>\n<li>Configure high\/low alarms (21.75\u201323mA or 3.5\u20133.75mA)<\/li>\n<li>Perform one-click zero calibration on 2-wire RTDs<\/li>\n<\/ul>\n<h2>Why Choose a Smart HART Temperature Transmitter Like the NCS-TT106H?<\/h2>\n<p>Modern plants choose smart HART transmitters because they deliver:<\/p>\n<ul>\n<li>Lower installation and maintenance cost (same two wires carry everything)<\/li>\n<li>Better accuracy and stability (\u00b10.15\u00b0C for PT100)<\/li>\n<li>Remote diagnostics that reduce unplanned downtime<\/li>\n<li>Future-proofing (easy integration with IIoT and digital twins)<\/li>\n<li>Wide operating range (-40\u00b0C to +85\u00b0C ambient)<\/li>\n<\/ul>\n<p>The Microcyber NCS-TT106H is an excellent example: ultra-compact \u03a645\u00d723mm head-mounted design, IEC61158-2 bus cable compatibility, 1000VAC isolation, and full support for both 4-20mA and multidrop HART networking.<\/p>\n<h2>Common Questions Engineers Still Ask<\/h2>\n<p><strong>Q: Can I use a HART transmitter in a pure 4-20mA system?<\/strong><br \/>\nA: Yes \u2014 it works exactly like a traditional transmitter. The digital HART layer is simply ignored.<\/p>\n<p><strong>Q: Do I need special cable for HART?<\/strong><br \/>\nA: Use shielded twisted-pair cable per IEC61158-2 for best performance, but standard instrument cable often works for short runs.<\/p>\n<p><strong>Q: How many devices can share one HART loop?<\/strong><br \/>\nA: In multidrop mode (digital only), up to 64 devices with unique addresses 0\u201363. In normal 4-20mA mode, only one device per loop.<\/p>\n<h2>Final Thoughts: Is a <a href=\"https:\/\/www.microcybers.com\/en\/head-mounted-1-ch-hart-temperature-transmitter\/\">Smart HART Temperature Transmitter<\/a> Right for Your Plant?<\/h2>\n<p>Whether you are upgrading an old analog system or designing a new greenfield project, a smart HART temperature transmitter offers the perfect balance of proven analog reliability and modern digital intelligence.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve searched \u201cWhat is a temperature transmitter with HART?\u201d, \u201cWhat is HART in transmitter?\u201d, \u201cWhat is the difference between 4\/20mA and HART?\u201d, \u201cWhat is the smart HART temperature transmitter?\u201d, or \u201cWhat are the 4 types of temperature sensors?\u201d, you\u2019re not alone. These are some of the most common questions engineers, technicians, and procurement teams [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7991,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[37,38],"tags":[],"class_list":["post-7988","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-and-events","category-products-and-services"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What is a HART Temperature Transmitter? Complete Guide + 4-20mA vs HART<\/title>\n<meta name=\"description\" content=\"What is a temperature transmitter with HART? What does HART mean in transmitters? Difference between 4-20mA and HART? What is a smart HART temperature transmitter? What are the 4 types of temperature sensors? Full beginner-to-expert guide with real examples.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.microcybers.com\/en\/what-is-a-hart-temperature-transmitter\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is a HART Temperature Transmitter? Complete Guide + 4-20mA vs HART\" \/>\n<meta property=\"og:description\" content=\"What is a temperature transmitter with HART? What does HART mean in transmitters? Difference between 4-20mA and HART? What is a smart HART temperature transmitter? What are the 4 types of temperature sensors? Full beginner-to-expert guide with real examples.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.microcybers.com\/en\/what-is-a-hart-temperature-transmitter\/\" \/>\n<meta property=\"og:site_name\" content=\"Microcybers\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-25T08:20:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-25T08:53:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"author\" content=\"microcyber\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"microcyber\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/\",\"url\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/\",\"name\":\"What is a HART Temperature Transmitter? Complete Guide + 4-20mA vs HART\",\"isPartOf\":{\"@id\":\"https:\/\/microcybers.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif\",\"datePublished\":\"2026-03-25T08:20:57+00:00\",\"dateModified\":\"2026-03-25T08:53:18+00:00\",\"author\":{\"@id\":\"https:\/\/microcybers.com\/#\/schema\/person\/983bd43eb81f49e7b7975a6f67287b2e\"},\"description\":\"What is a temperature transmitter with HART? What does HART mean in transmitters? Difference between 4-20mA and HART? What is a smart HART temperature transmitter? What are the 4 types of temperature sensors? Full beginner-to-expert guide with real examples.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#primaryimage\",\"url\":\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif\",\"contentUrl\":\"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif\",\"width\":700,\"height\":355},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.microcybers.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is a HART Temperature Transmitter?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/microcybers.com\/#website\",\"url\":\"https:\/\/microcybers.com\/\",\"name\":\"Microcybers\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/microcybers.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/microcybers.com\/#\/schema\/person\/983bd43eb81f49e7b7975a6f67287b2e\",\"name\":\"microcyber\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/microcybers.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/cb7fdf2d1483e1292c543a47b2753c720a9077c67a54355dab69317d06d6e392?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/cb7fdf2d1483e1292c543a47b2753c720a9077c67a54355dab69317d06d6e392?s=96&d=mm&r=g\",\"caption\":\"microcyber\"},\"sameAs\":[\"https:\/\/www.microcybers.com\"],\"url\":\"https:\/\/www.microcybers.com\/en\/author\/huang-xinmicrocyber-cn\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is a HART Temperature Transmitter? Complete Guide + 4-20mA vs HART","description":"What is a temperature transmitter with HART? What does HART mean in transmitters? Difference between 4-20mA and HART? What is a smart HART temperature transmitter? What are the 4 types of temperature sensors? Full beginner-to-expert guide with real examples.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.microcybers.com\/en\/what-is-a-hart-temperature-transmitter\/","og_locale":"en_US","og_type":"article","og_title":"What is a HART Temperature Transmitter? Complete Guide + 4-20mA vs HART","og_description":"What is a temperature transmitter with HART? What does HART mean in transmitters? Difference between 4-20mA and HART? What is a smart HART temperature transmitter? What are the 4 types of temperature sensors? Full beginner-to-expert guide with real examples.","og_url":"https:\/\/www.microcybers.com\/en\/what-is-a-hart-temperature-transmitter\/","og_site_name":"Microcybers","article_published_time":"2026-03-25T08:20:57+00:00","article_modified_time":"2026-03-25T08:53:18+00:00","og_image":[{"width":700,"height":355,"url":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif","type":"image\/gif"}],"author":"microcyber","twitter_card":"summary_large_image","twitter_misc":{"Written by":"microcyber","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/","url":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/","name":"What is a HART Temperature Transmitter? Complete Guide + 4-20mA vs HART","isPartOf":{"@id":"https:\/\/microcybers.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#primaryimage"},"image":{"@id":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#primaryimage"},"thumbnailUrl":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif","datePublished":"2026-03-25T08:20:57+00:00","dateModified":"2026-03-25T08:53:18+00:00","author":{"@id":"https:\/\/microcybers.com\/#\/schema\/person\/983bd43eb81f49e7b7975a6f67287b2e"},"description":"What is a temperature transmitter with HART? What does HART mean in transmitters? Difference between 4-20mA and HART? What is a smart HART temperature transmitter? What are the 4 types of temperature sensors? Full beginner-to-expert guide with real examples.","breadcrumb":{"@id":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#primaryimage","url":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif","contentUrl":"https:\/\/www.microcybers.com\/wp-content\/uploads\/2026\/03\/What-is-a-HART-Temperature-Transmitter.gif","width":700,"height":355},{"@type":"BreadcrumbList","@id":"https:\/\/www.microcybers.com\/what-is-a-hart-temperature-transmitter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.microcybers.com\/"},{"@type":"ListItem","position":2,"name":"What is a HART Temperature Transmitter?"}]},{"@type":"WebSite","@id":"https:\/\/microcybers.com\/#website","url":"https:\/\/microcybers.com\/","name":"Microcybers","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/microcybers.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/microcybers.com\/#\/schema\/person\/983bd43eb81f49e7b7975a6f67287b2e","name":"microcyber","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/microcybers.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/cb7fdf2d1483e1292c543a47b2753c720a9077c67a54355dab69317d06d6e392?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/cb7fdf2d1483e1292c543a47b2753c720a9077c67a54355dab69317d06d6e392?s=96&d=mm&r=g","caption":"microcyber"},"sameAs":["https:\/\/www.microcybers.com"],"url":"https:\/\/www.microcybers.com\/en\/author\/huang-xinmicrocyber-cn\/"}]}},"_links":{"self":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts\/7988","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/comments?post=7988"}],"version-history":[{"count":4,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts\/7988\/revisions"}],"predecessor-version":[{"id":7995,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/posts\/7988\/revisions\/7995"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/media\/7991"}],"wp:attachment":[{"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/media?parent=7988"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/categories?post=7988"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.microcybers.com\/en\/wp-json\/wp\/v2\/tags?post=7988"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}