NCS-TT305H Dual-Channel HART Transmitter

NCS TT305

Product Overview

The NCS-TT305 series HART temperature transmitter is a TÜV-certified high-precision, low-temperature-drift, and high-reliability product, serving as an important field device in process control. This device integrates a rich set of functional modules, enabling both general detection functions and complex control strategies.

The NCS-TT305 series temperature transmitter supports 4–20 mA + HART protocol and LCD display, and can be widely used in industries such as petroleum, chemical, power, and metallurgy.

Output Signal 4–20mA + HART, Burst Mode Supported
Protocol Version HART 7
Supply Voltage Non-Ex: (13~45)VDC; Ex d: (13~45)VDC; Ex ia: (13~30)VDC
Sensor Wiring 2-wire, 3-wire, or 4-wire connection
Input Signal Types Resistance (Ω): 0~500Ω, 0~2000Ω, 0~4000Ω, 0~40000Ω;
RTD: Cu50, Cu50_GOST, Cu100, Cu100_GOST, Pt50_GOST, Callendar-Van Dusen (Pt100), Pt100, Pt100_GOST, Pt200, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000;
Voltage (mV): -100mV~100mV;
Thermocouple (TC): B, E, J, K, N, R, S, T, L_GOST, A (W5ReW20Re), C (W5ReW26Re), D (W3ReW25Re), NiCrAuFe, CuAuFe
Channel Count Dual channel
Current Accuracy Current accuracy: 0.05%; Current temperature drift: 0.005%/°C
Electrical Isolation 2kVAC (test) / 50VAC (working)
Voltage Effect ±0.005%/V
Response Time 1.0~1.65s, depending on sensor type and wiring
Startup Time ≤10s
Damping Time Constant 0~32s
EMC IEC 61326
Explosion Protection IECEx: Ex ia IIC T6…T4 Ga;
ATEX: II2G Ex db IIC T6…T4 Gb, II2D Ex tb IIIC T85°C…T110°C Db
LCD Display Supported
Keypad Operation Supported (local button configuration)
Operating Temperature -40~85°C; optional -55~85°C
Humidity Range 5~95%RH
Storage Temperature -50~85°C
Alarm Signals Saturation Low: [3.75–4.0)mA, default 3.8mA;
Saturation High: (20–20.8]mA, default 20.5mA;
Alarm Low: [3.5–3.7]mA, default 3.6mA;
Alarm High: [21.0–23.0]mA, default 21.75mA
Vibration Specification 2–25Hz: ±1.6mm; 25–100Hz: ±4g
Dimensions 139.7 × 111.9 × 112.0mm
Housing Material Aluminum, Polycarbonate
Weight Approx. 1.67kg
  • Converts RTD, thermocouple, linear resistance, and millivolt (mV) input signals into a 4–20 mA output with HART 7 communication. Burst mode is supported.
  • Dual-channel sensor input supports sensor hot backup and cross-channel temperature drift monitoring between Sensor 1 and Sensor 2.
  • Hot backup automatically switches the loop output to the healthy sensor when the active channel fails due to an open or short circuit, ensuring uninterrupted process measurement without manual intervention.
  • Supports corrosion detection for 4-wire RTDs and 2-wire thermocouples by monitoring wiring resistance against configurable thresholds (RTD: 5–250 Ω, default 50 Ω; thermocouple: 5–10,000 Ω, default 5,000 Ω).
  • Supports multi-point linearization to improve measurement accuracy beyond standard factory calibration.
  • Advanced device diagnostics comply with the NE107 four-status model (Failure, Function Check, Out of Specification, and Maintenance Required), with independent alarm-level settings for Standard and SIL operating modes.
  • Integrated LCD display and push-button interface enable complete local configuration and diagnostics without requiring a HART modem.
  • Assessed in accordance with IEC 61508-2/-3 and IEC 61511 field-data requirements. Supports SIL 2 safety functions in single-channel (HFT = 0) architecture and SIL 3 in redundant (HFT = 1) architecture.
  • Available with intrinsically safe and flameproof explosion protection, including IECEx Ex ia IIC T6…T4 Ga and ATEX II2G Ex db IIC T6…T4 Gb / II2D Ex tb IIIC T85°C…T110°C Db certifications.
No files updated yet