NCS-TT106P Head-Mounted Single-Channel PA Temperature Transmitter

NCS-TT106P

Product Overview

NCS-TT106P Smart Temperature Transmitter is a single-channel modular temperature transmitter featuring high reliability, excellent long-term stability, high measurement accuracy, and low temperature drift. Equipped with advanced diagnostic functions, it meets the measurement requirements of critical process stages and serves as an indispensable field temperature measurement device in process control. It supports measurements from various types of resistance temperature detectors (RTDs), thermocouples (TCs), resistors (Ω), and voltage (mV) sensors, and is compatible with the Profibus PA communication protocol. The product has obtained multiple international certifications, including explosion-proof, CE-EMC, PAC, and EAC, and is widely used in process industries such as petroleum, chemical, power generation, and metallurgy.

Output Signal PROFIBUS PA
Protocol Version Profile 3.02
Supply Voltage Non-Ex: (9~32)VDC, quiescent current ≤14mA;
Ex: (9~17.5)VDC, quiescent current ≤14mA
Sensor Wiring 2-wire, 3-wire, or 4-wire connection
Input Signal Types Resistance (Ω): 0-500Ω, 0-4000Ω;
RTD: Cu50, Cu100, Pt100, Pt1000, Custom defined RTD;
Voltage (mV): -100mV~100mV;
Thermocouple (TC): B, E, J, K, N, R, S, T, Custom defined TC
Number of Channel Single channel
Accuracy Class Refer to user manual
Electrical Isolation 1KVAC
Voltage Effect ±0.005%/V
Response Time 0.5s
Startup Time ≤5s
Damping Time Constant (0~32)s
EMC IEC 61326 (GB/T 18268)
Explosion Protection Ex ia IIC T4 Ga
LCD Display Not supported
Button Operation Not supported
Operating Temperature (-40~85)℃
Humidity Range (5~95)%RH
Storage Temperature (-50~85)℃
Vibration Spec 2-25Hz: ±1.6mm; 25-100Hz: ±4g
Protection Level Terminals IP00; Module housing IP40
Weight Approx. 47g
  • Implements standardized communication in accordance with the PROFIBUS PA Profile 3.02.
  • Supports measurement of various RTDs, thermocouples, resistance and voltage signals.
  • Single-channel input; supports 2, 3, and 4-wire connections for RTDs.
  • High accuracy (Pt100: ±0.1°C), low temperature drift (Pt100: ±0.003°C/°C).
  • External Pt100 for cold-junction compensation, with accuracy up to ±0.15°C.
  • Open-circuit/short-circuit detection to assist in identifying sensor faults.
  • Complies with FISCO intrinsically safe explosion-proof requirements, enabling safe operation in hazardous areas.
  • Standard DIN Type B sensor head mounting.
  • PI organization certified.
  • Provides GSD/EDD files for compatibility with various DCS systems.

Inquiry information